Megger testing procedure pdf

Any help would be m megger testing procedures ieee electrical code issues engtips. The following is a summary of insulation resistance ir testing commonly referred to as megger testing of low voltage cables rated less than 5 kv, recognized by nexans. Examine the resistance values you have entered in your table. The equipment youre testing will determine how you hook up your meghommeter.

The possibility exists that a fault in the power system will cause a high current to flow into the ground system while the test is in progress. Well learn how to identify windings, check windings resistance and insulation resistance. With 4,7 5,8 6,9 connected together, perform a standard continuity test between 1,2 1,3 2,3 to make sure there are no blown open windings within the motor. Jan 19, 2018 its actually an insualtion resistance test. Aug 16, 2014 the procedure of the insulation resistance test are given below first, disconnect all the line and neutral terminals of the transformer. Getting down to earth 1 introduction nothing is quite so common or abundantly available throughout the world as the earths soil. Iso 9001 is the only standard in the 9000 family that can be certified.

Megger guide to electrical insulation testing pdf instrumart. These motors run conveyor belts, pumps, fans, and many other applications. In this video you will find out how to test 3phase induction motor. Threephase dualvoltage motor insulation resistance testing. Oct 25, 2018 insulation resistance tests megger test are carried out on all windings, core and core clamping bolts. The complete guide to electrical insulation testing. Standard for acceptance testing specifications for electrical. What is the megger test procedure for transformers.

A megger is an ohmmeter that measures resistance in the megohm scale. Test interphase resistance by disconnecting the leads from each terminal with a flathead screwdriver, then touch any two terminals with the two probes. Threephase dualvoltage motor insulation resistance testing threephase dualvoltage motors are used for most daytoday operations in todays industrial plants. It is checked by touching the free ends of the leads together while the megger button is pressed on to check for zero. Megger testing of residential circuits inspectionnews. Check whether your model has an integrated voltage tester for live circuits. Megger testing does not cause any damage, making it a good option when. A guide to low resistance testing test equipment depot. Continue with this testing procedure until you have values for all the spaces of your table. Ieee std 432000 recommends a procedure for measuring insulation resistance of armature and field windings in rotating machines.

Use meggers on highresistance measurements only such as insulation measurements or to check two separate conductors on a cable. In addition to these uses of this test, the working principle, operation procedure, types, and applications have also been discussed. Earth test and ground resistance testers for electricians ensuring an effective earth system is essential in a telecommunications system, and megger is expert in earth testing having been there right from the start. Insulation resistance testing guide chauvin arnoux. Megger test procedure manufactured goods electromagnetism. Megger cable test equipment provides access to all of the technology needed to make informed cable management decisions through the different stages of the cables life cycle. Megger makes electrical test equipment to help you install, improve efficiency and extend the life of electrical assets and cable networks at high, medium and low voltage. The result obtained is a voltage value usually expressed in kilovolts kv. Insulation resistance testing is a nondestructive test procedure. Figure 2typical megger test instrument hookup to measure insulation resistance. The megger test is a method of testing making use of an insulation tester resistance meter that will help to verify the condition of electrical insulation. If it doesnt, check the circuits to be tested with a voltage tester to make sure they are not live. Aug 01, 2019 megger is also called as a megaohmmeter and is a device used for the testing of insulation resistance of a cable. Have anyone hear of a hi megger testing residential circuits as part of their home inspection.

Select 500 volts dc or volts dc as the test voltage on your megger, depending on the model you are using. Residue inside the sealing cap can be conductive and lead to false readings. Megger leads to be connected to lv and hv bushing studs to measure insulation resistance ir value in between the lv and hv windings. I have not personally ever used a megger but from what i understand that type of test would be very time consuming or am i missing something. The procedure of insulation resistance test or megger test are given below. Motors are susceptible to the gradual failure of their insulation resistance. Dielectric testing may be destructive in the event of a fault, depending on the test levels and. Hi, ive been asked to find an ieee or equivalent test procedure for meggering from the tleads in an mcc cubicle to the motor in the field. To view all our multimeter ranges go to an insulation tester like a megger can show a component failing that a normal. Insulation resistance testing of low voltage cables in the field. The procedure to test these cables is outlined below. Com 99 washington street melrose, ma 02176 phone 7816651400 toll free 18005178431 visit us at. Test performed so performed to know the insulation resistance value is. The test measures the insulation resistance between the phases andor between phase and ground.

Megger can provide advice to help you make specific tests. Megger is also called as a megaohmmeter and is a device used for the testing of insulation resistance of a cable. Transformer testing commissioning, routine, diagnostic megger. The following sections of the ansineta standard for acceptance testing specifications for.

Iso 9001 standards include maintaining records that document where raw materials and products were processed, planning stages of development for new products and testing those products at each stage and establishing formal procedures for situations dealing with nonconformance. This document will focus only on the tests that are of importance for field installers which are described as installation and maintenance tests. For other cable on a reel, insulation resistance testing can be performed provided the sealing caps are removed. There is an inherent safety problem in earth resistance testing that requires care and planning by the user of the test set. A catalogue, for quick reference, of the range of megger test instruments for the maintenance of electrical power systems. Neta developed specifications for the acceptance of new electrical apparatus prior to energization and for the maintenance of existing apparatus to determine its suitability to remain in service. According to the national electrical code, all values should be over 25 megohm. Megger testing procedures ieee electrical code issues. If one of the values differs substantially from all the. This may cause unexpected high voltages to appear at the current and voltage. Electrical test equipment power station to plug megger.

It is commonly used in the industry for acceptance testing prior to energizing the cable and for maintenance testing programs. The standard megger testing equipment is used, the line terminal of which is connected to the winding or core bolt under test. Megger offers a family of highquality insulation testers at. Com reference manual applications guide delta 4000 12 kv insulation diagnostic system zmah02e.

A megger testing device is shown in the figure below. How to use a megger to identify a faulty component youtube. Working principle of megger 4 comments electrical measuring instruments the megger insulation tester is an instrument used for measuring high resistances of the order of megaohms and for testing the insulation resistance. Megger safety precautions when you use a megger, you could be injured or damage equipment you are working on if the following minimum safety precautions are not observed. You do this by using a high voltage and looking for voltage leaking through the insulation. The above variables should be controlled as much as possible to promote accurate insulation resistance measurement data. It is important to remove sealing caps from both ends of the cable to be tested.

The electrical field tests recommended for routinely testing a transformer include. A protocol involving voltage level, time duration, intervals between tests and connection methods must be composed, taking into account the type and size of the equipment, its value and role in the production process and other factors. High power test and diagnostics combination for medium voltage cables. Section 7 of the ansineta standard for acceptance testing specifications for electrical power equipment and systems may be reproduced and used on a cut and paste basis for the particular type of equipment to be tested. This measurement is performed using an insulation tester, also called a megohmmeter. Insulation resistance quality of an electrical system degrades with time, environment condition i. Understanding insulation resistance testing pdf 0206 rev. The goal is to determine if the insulation of a wire has been compromised. After you make your connections, you apply the test voltage for 1 min. Find here insulation testing and continuity, power protection, power transformer testing, power cable infrastructure, cable fault location, general electrical test. For example, unless there is reason to be concerned about winding deformation, a leakage reactance test is probably not necessary. Mar 28, 2018 in this video you will find out how to test 3phase induction motor. How to test a threephase motor with a megger hunker. Today megger offers the finest line of 5 kv, 10 kv and 15 kv dc insulation resistance testers available anywhere.

Test performed so performed to know the insulation resistance value is known as megger test. To accomplish this, a test procedure should be established and used consistently over time. A practical guide to earth resistance testing leda electronics. The device is being used since 1889, popularity raised during 1920s, since long back devise is same in its uses and purpose of testing, few real improvement appeared in recent years with its design and quality of tester.

All earthing arrangements should be tested immediately after installation and at periodic intervals thereafter. Standard for acceptance testing specifications for. The leads used for connecting megger testing with the circuit should be fault free and the two connecting leads should have electrical continuity. This test is often performed by applying an ac voltage but can also be done with a dc voltage.

Timeresistance testing method this method is fairly independent of temperature and often. The international electrical testing association neta was formed in 1972 to establish uniform testing procedures for electrical equipment and apparatus. Cable testing and diagnostics various cable tests are carried out to spot potential failures before they can cause severe outages. Megger provides thoughtfully equipped transformer test instruments for routine screening needs. Obviously, its a good idea to have a basic familiarity with the item youre testing. These types of measurements require the unique characteristics of a low resistance ohmmeters fourwire test method, which is covered on page 9 in this booklet. Basically, you should know what is supposed to be insulated from what. Jul 06, 2016 the test generally applies between 100 and 5,000 v or more. We are more apt to think of earth as something to be.

841 1185 1013 136 969 1124 1282 1181 1520 1012 1318 100 657 1158 304 1502 583 705 464 669 1390 1134 1210 1442 952 576 520 1428 779 1296 1210 799 158 197 743 567